MINERAL PROCESSING EPC

xlwu@xinhaimining.net

Tel / Whatsapp : +139 5356 0679

Home > Products

Xinhai mineral processing equipment mainly include: grinding equipment, flotation equipment, dewatering equipment, magnetic separation equipment, and so on. Some of the equipment is Xinhai independent research and development, and has been awarded national patent.

turbiity meter for clarifier or thickerner

thickener clarifier Equipment Environmental XPRT

Kusters Water offers a complete line of heavy duty clarifiers and thickeners for all types of liquid solids separation. Every Kusters Water clarifier and thickener is designed in accordance with current national standards and incorporates the industrys latest technologies. The result is a top quality product that performs year after year

Get Price

Reactor Clarifier Ovivo

The Ovivo 174; Reactor Clarifier TM solids contact clarifiers are high rate vertical flow units combining chemical mixing, flocculation, coagulation settling and clarification in a single circular tank. Applications may include lime softening, color removal and turbidity removal in drinking water treatment. Ovivo also has an extensive knowledge and experience in the application of this

Get Price

Difference Between Clarifier and Thickener

The Difference Between a Clarifier and a Thickener is subtle as they will visually look the same. Fundamentally, thickeners and clarifiers are both used to settle solids which results in the separation of liquids and solids. Thickeners are used to concentrate solids, while clarifiers are used to purify liquids. A thickener will give you a high density underflow while a clarifier will not.

Get Price

Measure Turbidity and DO or pH in Secondary Clarifiers

Wastewater treatment technicians who need to measure turbidity and dissolved oxygen (DO) or pH levels in secondary clarifiers will find the dual channel T80 Universal Transmitter and Triton TR6 Turbidity Analyzer from Electro Chemical Devices, Inc. (ECD) (USA), can be easily combined with the S80 Intelligent Sensors to measure DO, pH or five other common liquid parameters.

Get Price

Lamella clarifier

The inclined plates mean the clarifier can operate with overflow rates 2 to 4 times that of traditional clarifiers which allow a greater influent flow rate and thus a more time efficient clarification process. Lamella clarifiers also offer a simple design without requiring the use of chemicals.

Get Price

Inclined Plate Clarifier Design and Sizing Procedure

Inclined Plate Clarifier (parallel plate, lamella) Theory of Operation. Basic concepts and theories of clarification. If you are unfamiliar with basic inclined plate clarifier (plate settler, parallel plate clarifier, lamella plate settler, etc.) design principles, a review of the quot;Inclined Plate Clarifier (parallel plate, lamella) Theory of Operationquot; might prove helpful.

Get Price

Measuring Turbidity and Suspended Solids in Clarifier

Measuring Turbidity and Suspended Solids in Clarifier Supernatant Introduction Supernatant is the liquid remaining above a sediment or precipitate after sedimentation. From sedimentation basins, thickeners or digesters, the supernatant is piped to succeeding treatment processes, or is recycled. Operators monitoring supernatant turbidity or

Get Price

Inclined Plate Clarifier Design and Sizing Procedure

Inclined Plate Clarifier (parallel plate, lamella) Theory of Operation. Basic concepts and theories of clarification. If you are unfamiliar with basic inclined plate clarifier (plate settler, parallel plate clarifier, lamella plate settler, etc.) design principles, a review of the quot;Inclined Plate Clarifier (parallel plate, lamella) Theory of Operationquot; might prove helpful.

Get Price

CHAPTER 3 SLUDGE THICKENING Marmara 220;niversitesi

activity. A well operated thickener will have a solids recovery of about 95% [3]. Design of Thickeners The thickening process takes place in a settling tank with long enough solids retention time. For example in secondary clarifiers of activated sludge systems both

Get Price

SLUDGE LEVEL Industrial Instruments nz online

Sludge Level Detection and Control in clarifiers and thickeners. Measuring the sludge blanket level in clarifiers or thickeners is challenging, but the EcoSmart has proved to be very reliable in South African applications. The smart sludge level sensor is mounted under water and an ultrasonic beam gives continuous sludge level measurements.

Get Price

Outotec Thickening technologies

002 Outotec Thickening technologies Innovation is standard Outotec thickeners and clarifiers operate in minerals processing, alumina, chemical, water treatment, industrial and effluent applications throughout the world. The first Outotec thickener was installed in 1985. The many innovative features of these units, including

Get Price

Beginners Guide to Thickeners Outotec

Beginners Guide to Thickeners; Beginners Guide to Thickeners. Thickening is a process where a slurry or solid liquid mixture is separated to a dense slurry containing most of the solids and an overflow of essentially clear water (or liquor in leaching processes).

Get Price

Wastewater Clarifier Performance Chicago

Oct 24, 20160183;32;This page provides information on the expected performance of primary and secondary clarifiers. Removal efficiencies, detention times, and other parameters have been summarized to provide a handy reference. Of course, every wastewater plant is different, with potentially vast differences between municipal and industrial wastewater systems.

Get Price

automation, coagulant controls, turbidity, flocculant

Mt. Fury Company is the recognized leader in automating polymer dosage in dewatering and clarification applications. Using on line suspended solids and turbidity meters in conjunction with our Dosage Supervisor controller, we provide systems to optimize coagulant and/or flocculant dosages, resulting in reduced treatment costs and more consistent operation.

Get Price

Process Turbidity Selection Guide Hach

TU5300 The next standard in the evolution of turbidity. Accurate and simple operation for low level turbidity measurement TU5400 Hach's most accurate option for measuring ultra low turbidity levels. Ideal for membrane filter effluent monitoring and early particle breakthrough detection.

Get Price

Instrumentation for the Water and Wastewater Industry

No need to remove the meter from the line Instrumentation for drinking water Rosemount T56 Turbidity System The Rosemount T56 Turbidity System continuously monitors water turbidity in drinking water applications. Compliant with U.S. EPA 180.1 and ISO 7021 Standards Best in class NTU measuring range allows for greater resolution and

Get Price

Thickener Control using Turbidity measurement.

Turbidity isn't likely to work. Density, on the other hand, should work fine, and there is a long history of density control of thickener underflow in the mining industry. You can use nuclear density or any other density meter that will stand up to the abrasion in the underflow. Walt Boyes Editor in Chief Control magazine ..controlglobal

Get Price

Chapter 05 Clarification SUEZ

These clarifiers are termed quot;upflowquot; because the water flows up toward the effluent launders as the suspended solids settle. They are characterized by increased solids contact through internal sludge recirculation. This is a key feature in maintaining a high clarity effluent and a major difference from horizontal clarifiers.

Get Price

Instrumentation for the Water and Wastewater Industry

No need to remove the meter from the line Instrumentation for drinking water Rosemount T56 Turbidity System The Rosemount T56 Turbidity System continuously monitors water turbidity in drinking water applications. Compliant with U.S. EPA 180.1 and ISO 7021 Standards Best in class NTU measuring range allows for greater resolution and

Get Price

WATER TREATMENT PLANT GWSSB

An ultrasonic flow meter with flow integrator The raw water shall be taken to the sludge blanket lamella clarifier, for removal of turbidity due to suspended solids. In the lamella clarifier, the incoming water shall be delivered near the The main function of sludge thickener is to increase the concentration of solids by removing

Get Price

TTC Clarometer Overflow Turbidity

CLAROMETER Overflow Turbidity. The CLAROMETER OVERFLOW TURBIDITY system produces a 4 20mA analogue signal proportional to the thickener overflow turbidity measurement. The sensitivity range is adjustable. The cabinet is mounted on the thickener bridge and the turbidity probe is immersed into the overflow via a stainless steel probe holder.

Get Price

Sludge Blanket Level Royce Water Technologies, Australia

The ENV100 Ultrasonic Sludge Blanket Level Meter, utilises enhanced ultrasonic technology to measure the sludge interface level in various types of clarifiers, settling tanks and thickeners with superior accuracy and reliability.

Get Price

Thickener optimization to reduce production costs

Thickener optimization to reduce your production costs Promass F 200 or Dosimass coriolis flow meter doses flocculant in relation to bed mass. For quality assurance and final confirmation of the water clarity, a turbidity sensor monitors the solid particle carry over.

Get Price

SLUDGE BLANKET MEASUREMENT Control Components

SLUDGE BLANKET METER CBX. Cerlic CBX is a reliable stationary Sludge Blanket Meter that measures suspended solids in liquids. The near infrared optical measuring head is . lowered into the clarifier or thickener. It will continuously measure suspended solids concentration versus liquid depth. The CBX has up to

Get Price

AltaFlo Ultra High Rate Thickeners / Clarifiers

AltaFlo Ultra High Rate Thickeners / Clarifiers The PHOENIX AltaFlo Thickener is a rake less thickener that provides ultra high rate mixing, flocculation, and internal dilution followed by clarification and positive sludge collection and removal in a single tank.

Get Price

CHAPTER 3 SLUDGE THICKENING Marmara 220;niversitesi

activity. A well operated thickener will have a solids recovery of about 95% [3]. Design of Thickeners The thickening process takes place in a settling tank with long enough solids retention time. For example in secondary clarifiers of activated sludge systems both

Get Price

Sludge Blanket Detectors Partech

Sludge Blanket Detection A common requirement in the operation of sewage, wastewater and water treatment works is to find the location of the interface between the high solids region of a settlement tank, picket fence thickener or clarifier and the relatively lower solids region above.

Get Price

automation, coagulant controls, turbidity, flocculant

Mt. Fury Company is the recognized leader in automating polymer dosage in dewatering and clarification applications. Using on line suspended solids and turbidity meters in conjunction with our Dosage Supervisor controller, we provide systems to optimize coagulant and/or flocculant dosages, resulting in reduced treatment costs and more consistent operation.

Get Price

TTC Clarometer Overflow Turbidity

CLAROMETER Overflow Turbidity. The CLAROMETER OVERFLOW TURBIDITY system produces a 4 20mA analogue signal proportional to the thickener overflow turbidity measurement. The sensitivity range is adjustable. The cabinet is mounted on the thickener bridge and the turbidity probe is immersed into the overflow via a stainless steel probe holder.

Get Price

Suspended Solids Density Meter Markland Specialty

This animation demonstrates how the Markland Suspended Solids Density Meter works. The sonic pulse passing through clear water returns a strong echo and the meter reads zero. Suspended solids absorb some of the sonic energy making the echo weaker and the meter

Get Price

What you need is what we can do!

If you have any questions about our products and services, please feel free to tell us anytime!